❖Features
Features
When the engine is started, starting and auxiliary batteries are separated
allowing only the starting battery to be charged. When the charge voltage
reaches 13.2 volts the VSR engages allowing both starting and auxiliary
batteries to be charged. When the engine is stopped and the battery voltage
falls below 12.8 volts the VSR disengages separating the start and auxiliary
batteries. The auxiliary battery continues to power any accessories without
risk of draining the starting battery.
Additionally, the ePOWER VSR range offers features like :
- No voltage loss
- Intelligent battery monitoring to prevent unwanted switching
- Starter battery priority
- Bipolar switching
- Voltage dependent switching
Applications
- Marine
- Caravans
- Camper vans
- RV’s
|
❖Specifications
Brand | Enerdrive
Model | EN-LBC1224-40
eescription | 10-bits precise µProcessor
Power supply | Auto detect 12 / 24V
Connection batteries | M6
Other connections | 6.3mm faston
Cable suggestion | 20mm2
Current consumption in OFF state | 12V 1.5mA / 24V 1.5mA
Current consumption in ON state | 13.5V 360mA / 27V 160mA
Minimum Charge time | 60 sec.
Fast OFF | < 11.8V (12V) / < 23.6V (24V) after 4 sec.
IP Rating | IP54
Weight (kg) | 0.11
Dimensions L x W x H (mm) | 46 x 46 x 80